Wastewater Treatment Systems by Digital Analysis Corp. labTREAT LT150 
0-150 GPM  
Lab Wastewater Treatment Systems 

labTREAT LT150 150 GPM Lab Wastewater Treatment System

Lab wastewater Treatment System 150 GPM 

Standard version of our labTREAT LT150 150 GPM Wastewater Treatment System


System Performance Specifications: Influent Characteristic: Flow 0-175 GPM, 150 GPM average / 9000 GPH max. Influent pH: 0 < pH < 14. Temperature 32-212F.

Effluent pH Range: typical 6.5 < pH < 8.5 (note: the effluent pH range is fully programmable through the operator interface).

Effluent Monitoring: As mandated by the local controlling authority and by most discharge permits continuous monitoring of effluent flow and pH is provided on a circular chart recorder, paperless recorder, or via a data logger. Additionally SCADA systems are available with automatic report generation.
The labTREAT family of lab wastes pH Adjustment systems are small, compact, wastewater treatment systems designed to neutralize acids and bases from any source.

The LT150 treatment system displayed here is capable of treating wastewater flows up to 150 GPM continuous and 175 GPM intermittent. With the use of an influent equalization system, which is standard on all of our neutralization systems, periodic flows in excess of 250 GPM can be handled.

The labTREAT family of pH Adjustment / neutralization systems are well suited to neutralize effluent from any source including pharmaceutical manufacturing, CIP wastes, university laboratories, and science labs. These systems are often equipped with cooling loops to provide cooling of hot CIP wastes.

Utilities, Weight, Dimensions: Electrical: 480VAC, 3 phase, 60 hz, 20 amp. Disconnect not required (a disconnect is provided on our MCP).

Air: Less than 1 SCFH @ 80 psig.

Dimensions: 84" x 158" x 96"(H) - Not including the optional influent equalization system.

Weight: Approx. 6250 lbs. dry (not including shipping crate).
All of our lab wastes pH Adjustment systems are supplied as complete "turnkey" packages. Prior to shipping all plumbing and electrical connections are complete and the neutralization system undergoes extensive burn in testing in our QC area including a wet / hydro test.

The Main Control Panel (MCP) is equipped with a main disconnect providing OSHA Lock Out / Tag Out (LOTO) and UL 508 compliance. Electrical requires a single point connection.

All of our pH adjustment systems utilize a fail safe valve on the discharge that immediately halts flow in the event of a discharge contravention, alarm or a loss of power. This valve requires a small air supply. If air is not available the same function is provided in an all electric configuration.
Construction: Tanks: PP, PE, XLPE, FRP, and all stainless alloys.

Pipe, Valves, and Fittings: PVC, CPVC, PP, PE, PVDF, and all stainless alloys.

Main Control Panel: All of our pH systems are controlled by an programmable logic controller (PLC) typically Allen-Bradley. All panels are built to NEC, UL 508 and OSHA standards.

Weight: Approx. 6500 lbs. dry (not including shipping crate).